The tool does not run |
Power unit not functioning | Check the power unit for power flow and pressure (15-24 lpm 105-140 bar) |
Couplers or hoses blocked | Remove restriction | |
Pressure and return line hoses reversed at ports | Be sure hoses are connected to their proper ports |
|
Mechanical failure of piston or automatic valve | Disassemble breaker and inspect for damaged parts | |
The tool does not hit effectively |
Power unit not functioning | Check power unit for power flow and pressure (15-24 lpm 105-140 bar) |
Couplers or hoses blocked | Remove restriction | |
Fluid too hot (above 140 °F/60 °C) | Provide cooler to maintain proper fluid temperature (130 °F/55 °C) |
|
Low accumulator charge (pressure hose will pulse more than normal) |
Recharge accumulator. Replace diaphragm if charge loss continues |
|
Tool operates slow |
Low gpm supply from power unit | Check power unit for proper flow (7-9 gpm/26-34 lpm) or 5-6 gpm /18-22 lpm |
High back-pressure | Check hydraulic system for excessive backpressure (over 200 psi/14 bar) |
|
Couplers or hoses blocked | Remove restriction |